Documentation for Allegheny County's Air Quality Data (as published at data.wprdc.org)

The following tables define codes used in the Hourly Air Quality Data table. The parameter field also appears in the Daily AQI Data. (The `parameter` definitions below are also backwards-compatible with the old-format Daily Air Quality Data and Hourly Air Quality Data tables.)

Descriptions of the measured parameters (parameter)

parameter description
AMBTEMP Ambient Temperature DegC
BAMRAW BAM Analog Input
BCSTAT Status of the Aethalometer: .0 – Good, .0 R – Good & Tape Advanced, Any other number – Bad
BLACK CARBON Black Carbon absorption of ultraviolet radiation at a wavelength of 880 nm
BP Barometric Pressure
BP2 Barometric Pressure
CO Carbon Monoxide
DT_DZ Delta-T, 10m-2m
FRIDGE Fridge Temperature DegC
H2S Hydrogen Sulfide
H2S_SO2 H2S plus SO2
INT_T Internal Temperature of the shelter or room where the monitors are located
MAXWS Maximum Instantaneous Wind Speed
NO Nitric Oxide
NO2 Nitrogen Dioxide
NOX Nitrogen Oxides
NOY Total Reactive Nitrogen
NOYDIF Total Reactive Nitrogen excluding Nitric Oxide (i.e. NOY – NO)
OUT_RH Outside Relative Humidity
OUT_T Outside Temperature
OZONE Ozone computed by Standard Averaging
OZONE2 Ozone computed by an Alternate Averaging Method
OZONE_B Ozone computed by Standard Averaging - Second Analyzer for Quality Assurance
PER_F Filter Life Used
PER_F2 Filter Life Used
PM10 Particulate Matter up to 10 micrometers in size; measured by a Tapered Element Oscillating Microbalance
PM10A Raw Data collected by a Beta Attenuation Monitor
PM10B Particulate Matter up to 10 micrometers in size; measured by a Beta Attenuation Monitor
PM10RAW Raw Data collected by a Beta Attenuation Monitor
PM10_640 Particulate Matter up to 10 micrometers in size; measured by a T640X Monitor
PM10_FL Filter Life Used
PM25 Particulate Matter up to 2.5 micrometers in size; measured by a Tapered Element Oscillating Microbalance
PM25(2) Particulate Matter up to 2.5 micrometers in size; measured by a Tapered Element Oscillating Microbalance; corrected seasonally to better correlate with the Federal Reference Method
PM25B Particulate Matter up to 2.5 micrometers in size; measured by a Beta Attenuation Monitor
PM25RAW Raw Data collected by a Beta Attenuation Monitor
PM25T Particulate Matter up to 2.5 micrometers in size; measured by a Beta Attenuation Monitor
PM25_640 Particulate Matter up to 2.5 micrometers in size; measured by a T640X Monitor
PM25_FL Filter Life Used
PMCOARSE Particulate Matter up to 10 micrometers in size, excluding Particulate Matter less than 2.5 micrometrs in size
Peak Wind Gust Maximum Instantaneous Wind Speed
RAINFALL Rainfall and Snow Melt (i.e. precipitation)
RH% Relative Humidity
RWD (Resultant Wind Direction) Vector Wind Direction
RWS (Resultant Wind Speed) Vector Wind Speed
SIGTHETA (Sigma Theta) Standard Deviation of the Wind Direction
SO2 Sulfur Dioxide
SO2PPM Sulfur Dioxide measured in ppm
SOLARRAD Solar Radiation
SONICWD Scalar Wind Direction
SONICWS Scalar Wind Speed
T1AT2M Ambient Temperature DegC at 2 meters above ground level
T2AT10M Ambient Temperature DegC at 10 meters above ground level
TAPE COUNT Increment of Tape used by the Aethalometer
UVPM Organic Carbon absorption of ultraviolet radiation at a wavelength of 370 nm
UV_RAD UV Component of Solar Radiation
WNDR Scalar Wind Direction
WNSP Scalar Wind Speed

Definitions of the flag codes used in the highest_flag field

flag type description source_of_flag
< Average Insufficient data for valid average Automatically applied by logger if less than 75% or defined % valid in Validation Settings.
> Average Sufficient data for valid average, but some data missing Automatically applied by logger if > 75% (or user-defined threshold) but < 100% of readings valid.
P Instantaneous Power Failure Power failure experienced (invalidates one base average).
D Instantaneous Channel Offline Channel disabled via user interface (Logger Toolbox in 8872).
T Instantaneous Out Of Control due to bad Cal Normally a CEM feature, if cal drift > OOC limit set in Calibration program, then channel invalid until a good cal is passed.
F Instantaneous Boiler Offline (CEM) Normally CEM feature, boiler is considered offline based on status input pattern configured in Validation settings.
B Instantaneous Bad Instrument Stations Instrument is considered offline based on configured status input pattern. Will also appear during periods of Modbus or RS-232 communication "dropouts" between logger and instrument.
C Instantaneous Instrument in Calibration Logger running calibration program affecting this instrument/channel.
M Instantaneous Instrument in Maintenance Channel disabled via user interface (Logger Toolbox in 8872) or via configured status input.
O Instantaneous Analog Overrange Single reading > full scale of analog range, invalidates the base average.
U Instantaneous Analog Underrange Single reading < negative end of full scale of analog range, invalidates the base average.
A Instantaneous Math Error Error executing math pack channel equation, most commonly divide by zero.
+ Instantaneous Maximum Reading Error Reading > configured "Maximum Reading", invalidates the base average.
- Instantaneous Minimum Reading Error Reading < configured "Minimum Reading", invalidates the base average.
R Instantaneous Rate of Change Error Reading changed from one reading to another > the configured rate of change limit.
H Average High High Limit Exceeded Average (e.g., 1m, 1h) value > configured limit.
L Average Low Low Limit Exceeded Average (e.g., 1m, 1h) value < configured limit.
h Average High Limit Exceeded Average (e.g., 1m, 1h) value > configured limit.
l Average Low Limit Exceeded Average (e.g., 1m, 1h) value < configured limit.
J Average High High Rate of Change Change from previous average > set limit.
j Average High Rate of Change Change from previous average > set limit.
V Instantaneous Digital Information #1 Configured status input pattern detected.
W Instantaneous Digital Information #2 Configured status input pattern detected.
X Instantaneous Digital Information #3 Configured status input pattern detected.
Y Instantaneous Digital Information #4 Configured status input pattern detected.
Z Instantaneous Digital Information #5 Configured status input pattern detected.
f Average Floor limit exceeded Average < configured Floor Limit, value changed to floor value.
c Average Ceiling limit exceeded Average > configured Ceiling Limit, value changed to ceiling value.
I Average Invalidated by Edit Manually applied by Data Analyst to Invalidate Data.
E Average Edited Data Automatocally applied by AirVision softwre if the Data Analyst edits the value.
? Average Suspect Data Manually applied by Data Analyst to indicate suspect data.